CONTACT INFORMATION:
View contact information...
Sr. I&E PROJECT LEAD / DESIGN / CONSTRUCTION / COMMISSIONING / TURNAROUND / QA-QC
Professional experience includes project completion in the Power, Refining, Chemical, and Offshore facilities of Alabama, Africa, Aruba, Arizona, California, Hong Kong, Indonesia, Kuwait, Louisiana, Mexico, Mississippi, Texas, Washington State, & Utah. This experience includes project, site, construction or turnaround management and experience with the N.E.C., O.S.H.A., ISO 9002, HAZOPS, SAFETY. I also have experience with the EPA's FEMS regulations for air emissions compliance monitoring and standard QA/QC Inspection Standards.
Technical skills include the engineering, specification, design, and installation of all control, analytical, or complex electro-mechanical instruments. This experience includes fiber optics, power distribution, lighting, grounding, and 480Vac motor controls. I am also proficient in AutoCAD 2005 for the production of any detailed engineering design packages or training and operations manuals.
Control systems experience includes many installations or expansions of HONEYWELL TDC 3000, FOXBORO I/A DCS's distributive control systems or GE, SEIMANS, and ALLEN BRADLEY PLC's. This experience includes the hardware specification, hardware placement, graphics production and system startup.
Maintenance and construction experience includes calibration, equipment placement, system startup, trouble shooting, commissioning, on-line or hot cut over operations, the development and implementation of preventive maintenance and equipment run time optimization programs.
Experienced with the following equipment & software:
HONEYWELL TDC 3000 – C-300, FOXBORO IA, ALLEN BRADLEY PLC 560, ALLEN BRADLEY CONTROL LOGIC, WINLOGIC, SIEMENS, AND BAILEY INFI90. AUTOCAD, INTOOLS, SAP, SETROUTE, PARAGON, PRIMAVERA P3, MSOFFICE, ACCESS, EXCEL, MSWORD, MSPROJECT, OUTLOOK, and POWERPOINT.
My straight time hourly rate is currently $60.00. I enjoy travel, responsibility, extended hours, and am able to manage high stress situations. I am available for interviews with one days notice and would be available to start a new assignment within two weeks of a signed offer letter.
Please feel free to contact me at your convenience.
Yours truly,
Robert Kelly
ROK/tjp
Resume of Robert (Rocky) Kelly Sr.
Sr. I&E PROJECT LEAD / DESIGN / CONSTRUCTION / COMMISSIONING / TURNAROUND / QA-QC
EDUCATION / TRAINING
Electrical Journeymen License 1978 - Certified National Electrical Inspector 1980 - Electrical Master's License 1983 - AAS Industrial Electronics 1985 -OSHA Hazardous Waste Management - DuPont Remedial Waste Management – Houston, South Texas, & Louisiana Safety Council - Honeywell Automation College, Fail Safe Controller Implementation, TPS System (GUS) Overview, and Implementation, PKS Experion Certification, TDC 3000 Operator Certification - Foxboro Training Institute - Allen Bradley Institute - Total Quality Plus TQP- ISO - N.E.C. - O.S.H.A. - I.S.A. - & CPR Certifications.
EQUIPMENT / SOFTWARE
HONEYWELL TDC 3000, FOXBORO IA, ALLEN BRADLEY PLC 560, ALLEN BRADLEY CONTROL LOGIC, WINLOGIC, SIEMENS, BAILEY INFI90. AUTOCAD, INTOOLS, SAP, SETROUTE, PARAGON, PRIMAVERA P3, MSOFFICE, ACCESS, EXCEL, MSWORD, MSPROJECT, OUTLOOK and POWERPOINT
EXPERIENCE
BEI ENGINEERING – PASADENA, TX (Present)
Sr. I& E Project Designer - Control Systems Specialist – Field Engineering
* Recruited & assigned to the Design Engineering Group in BEI's field office in Beaumont, TX.
* Assigned to the EXXON – MOBIL Hurricane IKE Damage Assessment & Recovery Team.
* Responsible for site surveys and field damage verification for instrumentation associated with open Management Of Change orders (MOC's)
* During engineering phase responsible for direction to third party engineering firms to complete instrument specifications, vendor quotes, site engineering, design, and production of system wiring diagrams including location plans, field junction boxes, marshaling cabinets, and loop drawings.
* During construction phase responsible for the installation of all field instrumentation, conduit, cable, and wiring terminations.
* During commissioning phase responsible for the successful commissioning and integration of all new or replaced instrument into the existing plant Honeywell TDC 3000 network.
* Responsible for lead & sponsorship of the Exxon Mobil PSSR process.
BERGAILA & ASSOCIATES (2008 - 2009)
Sr. I& E Project Lead - Control Systems Specialist
* Recruited & assigned to the Automation Engineering Group @ Mustang's office in Channelview, TX.
* Assigned to the CONOCO PHILLIPS HONEYWELL C-300 SULFUR RECOVERY UNIT Upgrade Project in Sweeny, TX.
* Responsible for instrument take-off and development of the instrument database.
* Responsible for the site surveys and P&ID field verifications.
* Responsible for the design and production of all system wiring diagrams including location plans, field junction boxes, marshalling cabinets, and INTOOLS loop drawings.
* Responsible for the development of a successful hot cut over plan and integration of all instruments into the new and existing plant Honeywell TDC 3000 network.
* In August of 2008 assigned to the CONOCO PHILLIPS C-200 NESHAPS & BLENDING Hurricane Damage Assessment & Recovery Team in Bell Chase, LA.
* Responsible for instrument take-off and development of the instrument database.
* Responsible for the site surveys and P&ID field verifications.
* Responsible for the design and production of all system wiring diagrams including location plans, field junction boxes, marshalling cabinets, and INTOOLS loop drawings.
* Responsible for the development of a successful hot cut over plan and integration of all instruments into the new and existing plant Honeywell TDC 3000 network.
BURN'S & McDONNELL ENGINEERING (2007 - 2008)
Sr. I&E Project Lead / Turnaround / Construction & Commissioning Lead
* Recruited & assigned to the Design Engineering Group @ MATATHON OIL ISBL ULSD Hydrotreater Project in Canton, OH.
* Responsible for the HONEYWELL hardware proposals, FAT verification,
* Responsible for verification of instrument take-off, and development of the IN TOOLS instrument database.
* Responsible for instrument specification sheets, vendor quotes and delivery scheduled of the same.
* During engineering design phase responsible for the design and production of all I&E system wiring diagrams including location plans, lighting & grounding details, field junction boxes, marshaling cabinets, and PLC wiring.
ENGLOBAL ENGINEERING EAG - BEAUMONT, TX (2006 - 2007)
Sr. I&E Project Designer / Turnaround Coordinator / Construction & Commissioning Lead
* Assigned to CONOCO PHILLIPS Refinery CSM UPGRADE Project in Ferndale, WA
* Responsible for the field walk down and HONEYWELL FEL verification, AutoCAD update, and review, of 31 P&ID'S.
* Responsible for instrument take-off, and development of the IN TOOLS instrument database.
* During engineering design phase responsible for the design and production of all I&E system wiring diagrams including location plans, lighting & grounding details, field junction boxes, marshaling cabinets, and PLC wiring.
* During construction phase responsible for the equipment placement, installation of all field instrumentation, conduit cable, and wiring terminations.
* During commissioning phase will be responsible for commissioning and integration of 390 new instrument loops into the existing plant Honeywell TDC 3000 network.
JV INDUSTRIAL EPC GROUP - LAPORTE, TX. (2005 - 2006)
Sr. I&E Project Designer / Turnaround Coordinator
* Assigned to VALERO Refinery Visbreaker Heater Project in San Nicholas, ARUBA
* Responsible for the H.A.Z.O.P. review and AutoCAD update of 20 P&ID'S.
* Responsible for instrument take-off, and development of the instrument database.
* During engineering design phase responsible for the design and production of all I&E system wiring diagrams including location plans, lighting & grounding details, field junction boxes, marshaling cabinets, and PLC wiring.
* During construction phase responsible for the equipment placement, installation of all field instrumentation, conduit cable, and wiring terminations.
* During commissioning phase responsible for commissioning and integration of 280 new instrument loops into the existing plant Honeywell TDC 3000 network.
CDI ENGINEERING @ LYONDELL CHEMICALS - LAKE CHARLES, LA (1998 – 2005)
Sr. I&E Designer – Turnaround Coordinator – Control Systems Specialist
* June of 2004 assigned to the Turnaround Management Team @ LYONDELL CHEMICALS – LAKE CHARLES, LA.
* Instrument & Electrical QA/QC and IT / Logistics Coordinator.
CDI ENGINEERING @ EQUISTAR CHEMICALS - CORPUS CHRISTI, TX
* January of 2004 assigned to the Olefins Turnaround Management Team @ EQUISTAR CHEMICALS - CORPUS
CHRISTI, TX.
* I&E Turnaround Coordinator & It Logistics coordinator.
CDI ENGINEERING @ EQUISTAR CHEMICALS - CHANNELVIEW, TX
Sr. I&E Designer – Turnaround Coordinator – Control Systems Specialist
* April of 2002 assigned to the 2003 OP1 Turnaround Management Team @ EQUISTAR CHEMICALS - CHANNELVIEW, TX. As the I&E Turnaround Coordinator.
* Responsible for the daily management of the I&E turnaround planners during the planning and scheduling phase. Responsible for Coordination of all Instrument, electrical and analyzer maintenance and construction activities. Main focal point for all management updates for I&E work.
* Identified issues needing engineering involvement (e.g., discovery damage/repairs).
* Resolved work flow issues (permits, material, etc.),
* Provided daily progress reports to Turnaround Manager. Primary point of contact role for I/E/A contractors.
* Responsible for the overall coordination of QA/QC for all turnaround IEA work.
* Responsible for the overall coordination of I&E job commissioning and closure executions.
* Proactively monitored and audited contractor safety and compliance to HSE procedures.
* Participated or lead safety meetings for assigned area including contractor safety meetings. Communicated with Area Operations Representatives, Contractor Supervision, and other T/A Coordinators to ensure safe, efficient execution of all C/M work.
* Worked with Planners/Schedulers to finalize and update overall integrated turnaround schedule.
* Submitted contractor performance reports for assigned contractors during the October 2003 turnaround execution phase.
CDI ENGINEERING @ EQUISTAR CHEMICALS - CORPUS CHRISTI, TX
Sr. I&E Designer – Turnaround Coordinator – Control Systems Specialist
* November of 2000 assigned to the 2001 Olefins Turnaround Management Team @ EQUISTAR CHEMICALS - CORPUS CHRISTI, TX. As the I&E Turnaround Coordinator.
* Responsible for the daily management of the I&E turnaround planners during the planning and scheduling phase
* Responsible for the construction, commissioning, and closure of all I&E job packages during the October 2001 turnaround execution phase.
* May 2000 assigned to the Plant Maintenance Engineering Group @ EQUISTAR CHEMICALS - CORPUS CHRISTI, TX.
* Responsible for I&E plant maintenance work requests and plant engineering requests. Also responsible for the engineering, design, construction, and commissioning of new instrumentation into the existing plant Honeywell DCS, ALLEN BRADLEY PLC'S, or TRICONICS systems.
* July of 1999 assigned to the Butadiene 2000 Turnaround Management Team @ EQUISTAR CHEMICALS - CORPUS CHRISTI, TX. As the I&E Turnaround Coordinator.
* Responsible for the daily management of the I&E turnaround planners during the planning and scheduling phase Responsible for the construction, commissioning, and closure of all I&E job packages during the March 2000 turnaround execution phase.
* May 1998 assigned to the Plant Maintenance Engineering Group @ CELANESE CHEMICALS, PAMPA, TX.
* Responsible for I&E plant maintenance work requests and plant design engineering requests.
MANPOWER TECHNICAL @ HONEYWELL - HOUSTON, TX (1997 - 1998)
I&E Capital Project Coordinator / Construction / Commissioning Lead
* January of 1997 assigned to HONEYWELL PROJECT @ AMOCO - SALT LAKE CITY, UT.
* Responsible for the H.A.Z.O.P. review and AutoCAD update of 124 P&ID'S.
* Responsible for the instrument take-off and development of the instrument database.
* Responsible for the site engineering, design, and production of all system wiring diagrams including location plans, field junction boxes, marshaling cabinets, and field termination assemblies.
* During construction phase responsible for the Honeywell equipment placement, the calibration and installation of all field instrumentation, including all conduits or cable installations and final the final field terminations.
* During commissioning phase responsible for the successful hot cut over and integration of 540 new instrument loops into the existing plant Honeywell TDC 3000 network.
CDI ENGINEERING @ EQUISTAR - CORPUS CHRISTI, TX (1996 - 1997)
I&E Project Designer / Coordinator / Construction / Commissioning Lead
* June of 1996 assigned to HONEYWELL PROJECT @ OXYCHEM - CORPUS CHRISTI, TX.
* Responsible for the H.A.Z.O.P. review and AutoCAD update of 56 P&ID'S.
* Responsible for instrument take-off, and development of the instrument database.
* During engineering phase responsible for the site engineering, design, and production of all system wiring diagrams including location plans, field junction boxes, marshaling cabinets, and field termination assemblies.
* During construction phase responsible for the Honeywell equipment placement, the installation of the field instrumentation, all conduit & cable installations, and final field terminations.
* During commissioning phase responsible for the successful hot cut over and integration of 140 new instrument loops into the existing plant Honeywell TDC 3000 network.