CONTACT INFORMATION:
View contact information...
Objective Seeking a position in the field of Engineering as Control Room Operator in a multifunctional organization.
Summary * More than eight years in steam plant operation and maintenance as Control Room Operator.* Familiar with the use of, hand and power tools including precision measuring instruments.* In depth knowledge of the mechanical and control systems.* Operation of the physical building and equipments.* Perform routine maintenance and repairs on mechanical, plumbing, lighting and electrical equipment.* Work with in the parameters of operating budget.* Skilled in blueprint and schematic reading, interpretation, and development.* EPA Rule 608 Type, Universal Technician Certification.* Unlimited Steam Engineer License from City of Los Angeles.
Experience 01/2008-08/2008 Cedars-Sinai Medical Center Los Angeles, CA
Control Room Operator (Central Plant)Using computerized systems perform a variety of skilled work in the operation, maintenance and repair of boiler, heating, air conditioning, ventilating, Building Automation Systems, Energy Management Systems, DDC Control, pneumatic, electrical, lighting, power, water treatment, and other mechanical systems. As a Control Room Operator operate and maintain all the equipment such as boilers, chillers, pumps, condensers, and compressors and start up, regulate, and shut down equipment in order to meet demands for heating, cooling. Make sure that the equipments are operating safely and economically and within established limits by monitoring meters, gauges, and other instruments attached to equipment. According to the need, make adjustments and perform repairs and maintenance whenever necessary. Also keep a log of all relevant events and facts concerning the operation and maintenance of the equipment.
12/2006-10/2007 Wilshire Grand Hotel & Centre Los Angeles, CA
Control Room Operator (Stationary Engineer)As Control Room Operator operate and maintain all the equipments such as boilers, chillers, pumps, condensers, and compressors. As Control Room Operator start up, regulate, and shut down equipment in order to meet demands for heating, cooling. Make sure that the equipments are operating safely and economically and within established limits by monitoring meters, gauges, and other instruments attached to equipment. According to the need, make adjustments and perform repairs and maintenance whenever necessary. Also keep a log of all relevant events and facts concerning the operation and maintenance of the equipment. On a steam boiler, observe, control, and keep records of steam pressure, temperature, water level, power output, and the amount of fuel consumed. Also test and chemically treat hydronic systems to prevent corrosion and harmful deposits. Supervision of operation, maintenance and repair of all mechanical systems in a building, industrial power plant and control room. As a Control Room Operator also perform routine maintenance, such as repairing and replacing pumps, motors and other operating equipment, lubricating moving parts, replacing filters, and removing soot and corrosion that can reduce operating efficiency.
10/1997-06/2003 Lights of America, Walnut, CA
Production EngineerSupervision of computer operated SANYO CHIP MOUNTER, SANYO GLUE DISPENSER, and Universal Radial-8 Sequencer Inserting Machine, Universal Radial-5 Sequencer Inserting Machine, Universal Axial Sequencer Inserting Machine, Radial Insertion Machine, Excellon Router/Drill Machine Pin & Barrel Inserting Machines and Knowledge of Programming & Data editing. Familiarity with DC drivers, PLCs A/C inverters drives and servo motors.
01/1986-02/1992 Karachi Electric Supply Corporation, Karachi Karachi, Pak.
Control Room OperatorAs a Control Room Operator typically use computers to operate the mechanical, electrical, and fire safety systems and monitor, adjust, and diagnose these systems from a central location, using a computer linked into the buildings' communications network. As a Control Room Operator observe Boiler Pressure, Boiler Temperature, Economizer, Super-Heater, Forced Draft Fan, Induced Draft Fan, & Gas Recirculation Fan, Coolers, Cooling system, Burners, Furnace, Furnace Pressure, Air Heater, Air Compressors, Boiler feed pumps, Condensate Pumps, High & low pressure Heaters, Evaporators, Deaerator, Chillers, Oil Units, Mechanical Valves, Pneumatic Valves, Blueprints Interpretation. Use of hand and power tools to perform maintenance and repair ranging from a complete overhaul to replacing defective valves, gaskets, or bearings. Also test the water in the boiler and add chemicals to prevent corrosion and harmful deposits. Check air quality of the ventilation system and make adjustments to keep the operation of the boiler within mandated guidelines. Servicing, troubleshooting, repairing, and monitoring modern systems all require the use of sophisticated electrical and electronic test equipment.
Education 2007-2008 California State University of Los Angeles Los Angeles, CA
* BSME (Enrolled) to complete Master in Mechanical Engineering
1991 NED University of Engineering and Technology, Karachi Karachi, Pak.
* B.S. Degree in Mechanical Engineering
1993 City of Los Angeles, CA Los Angeles, CA
* Unlimited Steam Engineer License/EPA Universal Tech. Certification (2007)
1982-1984 Karachi Electric Supply Corporation, Karachi, Pak Karachi, Pak.
* Three years Apprenticeship Training as a Control Room Operator
Computer Microsoft Windows XP, Microsoft office (Word, Power Point, Excel), Solidworks, Graph pad, Internet etc.
View contact information... |