CONTACT INFORMATION:
View contact information...
Post Applied For: Senior Electrical Technician
Total Experience: Sixteen (16) years
Personal Profile
Date of Birth: 02-June-1971
Nationality: Indian
Marital status: Married
Languages known: English, Tamil, Telugu, Hindi
Qualification Details
Educational Qualification
 S.S.C. completed the year of 1987-88
Technical qualification
 I.T.I. Electrician (Govt. of India) Completed the year of Aug'1989-July'91. (N.T.C)
 Diploma in Electrical Engineering Completed the year of 1992-95 Mumbai India (IETA)
Apprenticeship Qualification
 Apprenticeship Trainee Completed the Year of 1995 (NAC) by Bharat Heavy
Electrical Limited, Ranipet - India.
Additional Qualification
 Diploma Programme in Industrial safety at National Institute of Lab our Education
And Management Completed year of 2004.
Professional Qualification
 B.B.A at Madras University, Tamil Nadu, India.
Computer
 Having knowledge of Microsoft Office XL, PowerPoint, Windows word document
And internet,
Others
 Suggestion Award Certificate By Bharath Heavy Electrical Limited, Ranipet-India
 Electrical License B # 53598 Issued by Tamil Nadu Electricity Board-India.
Work Permit System Course attended at Kuwait Oil Company (KOC) Safety Department and Holding Executing Authority Card for all types of work permits.
Working Experience in India and Aboard
 16 years Experience in Electrical Project and Maintenance work
Employment Details In India and Abroad
1 Employer
Seconded by
Position
Period
: KUWAITOILCOMPANY(KSC)-KUWAIT.
: Kuwait industrial refinery Maint & Engineering
Company, KREMENCO- KUWAIT
: SENIOR ELECTRICAL TECHNICIAN
: From Sep 2006 to till date
(Maintenance)
2 Employer
Seconded by
Position
Period: EQUATE PETROCHMICAL CO-KUWAIT.
: KHARAFI NATIONAL CO -Kuwait.
: ELECTRICAL SUPERVISOR
: From March 2006 to April 2006 (2 month)
(Shutdown Maintenance)
3 Employer
Seconded by
Position
Period
: KUWAIT OIL COMPANY (KSC) KUWAIT.
: Al-Meer Technical Services Company-Kuwait.
: LEAD ELECTRICIAN
: From July 1999 to Sep 2005 (6.3 years)
(Maintenance)
4 Employer
Seconded by
Position
Period: BHARATH PETROLIUM CORPARATION (BPCL).
: Senthil Techno Crafts. Chennai, India
: SENIOR ELECTRICIAN
: From Nov' 1995 to May 1999 (3.6 years)
(Project and Maintenance)
5 Employer
Seconded by
Position
Period: INDIAN OIL CORPARATION LTD (IOCL) INDIA
: YES JAY ENGINEERING. Chennai, India
: ELECTRICIAN.
: From Aug' 1991 to Sep' 1994. (3 years)
(Project and maintenance)
6 Employer
Position
Period: BHARATH HEAVY ELECTRICALS LTD
RANIPET INDIA (BHEL)
: ELECTRICAL TRAINEE
: From Oct 1994 to Oct 1995 (1 year)
(Maintenance Trainee)
NATURE OF JOB
Erection, Commissioning, Testing, Operation, Maintenance and Troubleshooting of all Electrical Equipments, for Power and distribution transformer, Generator, HV,MV,and LV Motors, HV, MV Switch gear and panels, HV,MV and LV Power and Control Cables & Glanding, Protection Relays, MCC Panels and Motor Starter, Grid Ear things, VSD Motors, CT and PT, Batteries and Battery Chargers, UPS & Rectifiers, Power and Control Circuit, Industrial Lightings, PDB and LDB, MOV and ROV, DCS and PLC, Cathodes Protection Rectifier (CPR), Fire and Gas, Heat Tracing Cables for LCV,PCV and pipe lines, All Electrical Testing Equipments, Hazardous Area Classification and PTW, Plant Strat up and Shut down Activities. In Kuwait Oil Company (KOC) Kuwait, Gathering Center, Gas Booster Station, Water Treatment Plant, Water Injection Plant, Well Head, Equate Petrochemical Plant Kuwait, Indian oil Corporation (IOCL) India, Bharath Petroleum Corporation (BPCL) India, Bharath Heavy Electrical LTD (BHEL) India, for working in the following electrical equipments,
WORKING EXPERIENCE IN ABROAD AND INDIA
Maintenance and Project
 Daily Routine Maintenance:- Carried out day to day, Preventive, corrective and break down maintenance activities on electrical systems and in assigned field, covering gas turbine generators and controls, LV/HV motors and control circuits, transformer, vessels, tanks, valves and piping, well head controls, distributed control system DCS, Programmable logic controllers, UPS, Batteries, HV,LV Substations, MVSG, HVSG, Cables, HV overhead lines, electrical submersible pumps (ESP) and electrical protection system. This includes receiving work orders and repair work requests,
 Material Request:- Determining priorities in conjunction with supervisor, identifies and orders required materials, spares and equipment, liaises with counterpart in maintenance and operations to release desired equipment and plant and executing work on site and or in workshop.
 Safe Work Permit:- Implement and observes the company's HSE policies and procedures
Cold, hot, Vehicle Entry, Confined Space and Electrical Isolation HV,LV Work permit.
 Co-Ordination of Maintenance Work:- Assisted with operation, Instrument and Mechanical Maintenance department for shutdown, start up and troubleshooting activities.
 Transformer: - Erection, commissioning, Testing, maintenance and Troubleshooting of
33/11Kv,11kv/3.3Kv,11/0.440kv Indoor and outdoor type up to 5MVA Power distribution Transformer ABB, FG Wilson, Vijay Electrical, Siemens, and Lucy, AL-Ahleia
 Generator's: - Erection, Commissioning, Testing, Maintenance, and troubleshooting Of generators, Control Panel, automatic changeover Switch, Mechanical Changeover Switch Interlocking system and AVR, alternators up to 5MVA Cater Filler, GE, Perkins, Kirlosker, FG Wilson, and General Electrical Companies.
 HV, MV, and LV Motors:- Erection, Commissioning, Testing, Maintenance and Troubleshooting of H.V, MV,LV Motor Breakers and Starters DOL, Star Delta, Auto Transformers Starter UP to 2MW, for all type of companies
 HV, MV Switch gear and Breakers panels: - Erection, Commissioning, Testing, Maintenance and troubleshooting of HV, MV and LV Switch Gear and Breakers, MCB, OCB, ACB, MOCB, RMU, SF6, ELCB, GIS, GFCI, HRC fuses. For al-Ahleia, GE, Siemens, S&I and Ebomac Companies.
 CT and PT: - Operation Maintenance of CT, VT, and PT for Measuring and Protection of Feeders and Motors.
 HV,MV and LV Power and Control Cables & Glanding: -Cable Laying, Glanding, Testing loop Checking, Termination and Lugs of cables up to 400 sq mm, MICC, PVC,
XLPE, PILC, 4C and Single Core Cables all Type of Company's
 Batteries and Chargers: - Erection, Commissioning, Testing, and Maintenance of Batteries, and Battery Charger for Lead Acid Cell and Alkaline cell for cater pillar, Soft, Nife, and Chloride
 Companies.
 UPS:- Erection, Commissioning, Testing, Maintenance and Troubleshooting of UPS up to 110V Control Supply for HT & LT Substation Panel's Boards, Instruments Control Panels PLC & DCS Systems, for Soft, Chloride, Gutor, Knife Companies.
 CPR: - Operation, Maintenance and Troubleshooting of Cathodes Protection Rectifier Anode and Cathode AC to DC Rectifiers Transformer Using Pipelines and vessels avoid corrosion.
 Lightings: - Erection, Commissioning, Testing, Maintenance and Troubleshooting of all types of lighting's, Tower Light, Street Light, Industrial and Offices. Hazard's Area Explosion proof Light Fittings S.V, MV, Metal alloyed, halogen, Emergency Light Fittings, Lighting Generators set and Using Lux Meter.
 Ear thing Systems:- Maintenance of all Type of Grid Earthing Network for all Electrical
 Protection Relays:- Motors, Transformers, Generators, Feeders, all types of Relays, Over Current, Earth Fault, Restricted Earth Fault, Stalling, Over Load, Thermal over Current Relay, Commissioning and Testing with Injection Kit.
 Electrical Testing Equipment:- Using of Megger, AVO Meter, Cable Route Locator, Fault Locator, Burning kit, Hi-Pot Test Kit, Primary & Secondary Injection Kit, Earth Megger, Phases Sequence Meter, Taco Meter, Phasing Stick, Earth Stick all type of Electrical Equipments Testing in hazardous area using intrinsically safe meter used.
 Zone Classification:- Zone 0, Zone 1, Zone 2, Température Classification, Obtain safe work Permit cold, Hot, Vehicle, Vessel, EX, EXD Explosion proops.
 Drawings: - Reading Power and Control Circuit for MCC panel, Motors, switchgear Control Panel, Substation & Ring Main Unit.
 Plant start up and shut down sequence. Trouble shooting of heat transfer units, Boiler, compressor, Super Heaters, Desalted Plant, Motors, Condensate Requiring Unit and Turbine.
View contact information... |